| Motion
detector for
ceiling 1000 W |
|||||
| Code
x2981 |
|||||
| 127 Volt | |||||
![]() |
![]() |
||||
| Function: | |||||
| -It
allows to detect people`s motion within an area and ignition the one or
more lamps, for some time ( to be ajusted ), and close in later. -It also allows to adjust, though an ambiance light intensity detector, the ambiance light threshold requiered. -Suitable for the light control by corridors, stairs, garage, bath, etc, and where requiered by any other ambit for automatic opening for motion detection and timed closing purposes.It is also used to control the supply of any appliance that may comply with the technical characteristics of this unit. |
|||||
| Operation: | |||||
| -Fully automatic operation. | |||||
| Installation: | |||||
| -It
should be installed on the ceilling ( eventually on the wall ) fastened
to an embedded box or with screws with wooden pegs. -To be used indoors only. -After the instalation, ignition time and ambiance light sensitivity should be adjusted with the corresponding preset device. -Before carrying out the installation,the general electric power switch of the entire premises must be shut off. |
|||||
| Technical features: | |||||
|
• Supply voltage: 127 V Maximum range: 6 meters (to 20º C) Detection angle: 360º Open angle: 110º On time: de 7 seg. Operation by ambiance light: de 0,1 a 6.000 lux. • Oulet to Relay. • class II device • Indoore use • Weigth: 110 gr. |
|||||
| Wiring
diagrams: |
|||||
![]() ![]() |
|||||
|---|---|---|---|---|---|
![]() |
|||||
|
Detection area: |
Maximum power per load type: | ||||
![]() The maximum areas is calculated considering the detection area transversely. |
![]() |
||||
|
|||||