Low
and over voltage protector |
||||
| 1900
W |
||||
| Code
x1101 |
||||
| 127 Volt | ||||
![]() ![]() |
![]() |
|||
| Function: | ||||
| -
It stops the electrical supply to any appliance or equipment connected.
When the network voltage has fluctuations that may damage the appliances,
once the voltage gets normal again, the supply returns automatically (with
some delay). - Appropriate to be used in protection of refrigerators, washing machine, water pumps, microwaves, tv, computers, etc. |
||||
| Operation: | ||||
| - The disconnection and reconnection of supply are fully automated. | ||||
| Installation: | ||||
| -
It can be connected alternatively, between the wall socket oulet and the
plug of the appliance to be protected. - To be used indoors only. |
||||
| Wiring diagrams: | ||||
![]() |
||||
| Technical
features: |
Maximum power per load type: | |||
|
Supply voltage: 127 V Protection range: - Over - voltage opening: 252 V - Low - voltage opening: 168 V Desconnection delay: 20 miliseconds. Reconection delay: 2 to 4 minutes. It has voltage indicators (Low, Normall and High) for color led. Oulet to triac. To control higher power a higer power unit should be used.( to see Code 1105). class II device Indoore use Weigth: 125 gr. |
In case the installation has the maximum load (resistive and reactive), the maximum power to be considered is 500 VA. |
|||
| |
||||
|
Keep off any item, in order to improve ventilation. |
||||
| Downloads: | ||||
| |
||||