| Stairs
timer 5 KW |
||||
| Code
0907 |
||||
| 220 Volt | ||||
![]() |
Dimensions (mm) (W x H x D) | |||
![]() |
||||
| Function: | ||||
| -
It allows keeping ligthtingset, from an adjustable time on by pressing
a standard auxiliary switch. - Suitable for the light control of corridors, stairways, parking space and any other place, where requiered for manual ignition and timedturning - off purposes.It is also used to control the supply of any appliance that may comply with the technical characteristics of this unit. |
||||
| Operation: | ||||
| -
It is operated by pressing manually the standard auxiliary switch, then
timing turns off automatic. - If the unit is timing and any of the standard auxiliary switches is activated, timing restarts. -If the ligth is requiered to be on permanently, the command can be changed to permanentlu on, through the front switch in "Direct" position. |
||||
| Installation: | ||||
| -
Install into a box with DIN rail. - Then some standard switches ( no more than 30 ) are conected in parallel to the unit, so as to operate as auxiliary switches. - To be used indoors only. - After the installation, ignition time should be adjusted by the front knob. - Before carrying out the installation,the general electric power switch of the entire premises must be shut off. |
||||
| Wiring diagrams : | Maximum
power per load type: |
|||
![]() |
![]() In
case the installation has mixed load (resistive and reactive), the maximum
power to be considered is 2,500 VA. |
|||
| Technical
features: |
||||
| •
Supply voltage: 220 V • Timing: adjustable with in 27 second • It has a By-pass switch for permanent ignition. • Oulet to Relay. • Support: DIN rail. • class II device •- Indoore use • Weigth: 130 gr. |
||||